U-Panel

U-Panel is an exposed fastener wall and roof panel. With a ¾” (approximate) rib height and 6” on center rib spacing, U-panel offers a lower profile and softer appearance than R-Panel or Multi-Rib. U-Panel is also widely utilized as a liner panel or partition wall.

Details

  • Minimum slope: 2:12 (with sealant)

  • Oil Canning is a natural occurrence in metal panels and is not a cause for panel rejection

Testing Data

  • Fire Rating: Class A
  • Uplift Test : UL580 Class 90
  • Class 4 Impact Resistance: UL 2218
  • Florida State Approval: 8885.1
  • IAPMO Approval: ER-0270
  • Fire Resistance: UL263

  • For any available Test Data, Section Properties or Load Tables, please visit our downloads section

Panel Options

  • Roof panels:
    purlin bearing leg required
  • Wall panels:
    non-purlin bearing leg optional
  • Coating:
    - Kynar 500® (PVDF) 

    Silicone Modified Polyester (SMP)
  • Substrate:
    - Standard 26 GA Galvalume®
      (roof and wall panels)

    - Optional 24 and 22 GA Galvalume
      (wall panels)

    - Optional 29 GA Galvalume
      (Liner Panels - Narrow Coverage)