7th Street Wharf- During New Orleans, LA 238T

238T Metal-Over-Metal Recover – Standing Seam Metal Roof System

Recover aging metal roofs quickly and cleanly—without tear-off or disruption.

McElroy Metal’s 238T Metal-Over-Metal Recover System installs directly over existing metal roofs, providing a frameless, long-term replacement solution without tear-off or disposal. Its symmetrical standing seam design allows installers to start or stop anywhere on the roof and remove or replace individual panels as needed.

Renderings & Profiles

Great for:

walls-icon
WALLS
roofs-icon
ROOFS
residential-icon
RESIDENTIAL
commercial-icon
COMMERCIAL
238t plank and pencil rib
Mini-Rib East Dallas Townhouse 4
238T Metal-Over-Metal Recover – Standing Seam Metal Roof System Specs at a Glance
Panel Type
Rib Height
Major Rib On Center
Cover Width
Factory Panel Length
Onsite Forming Available
Substrate/Gauges
Installation
Finishes
Minimum Slope
Concealed fastener, mechanically seamed
2 3/8”
16", 18” or 24” (site formed only)
16", 18” or 24” (site formed only)
Up to 80' (varies by manufacturing facility)
Yes
24 GA Galvalume®-see notes below for additional options
Solid Deck or Open Framing
Kynar 500® (PVDF); Galvalume® Plus (acrylic-coated)
½:12

238T Metal-Over-Metal Recover Ideal Applications

  • Commercial, industrial, and institutional buildings with aging metal roofs.

  • Facilities requiring uninterrupted operations where tear-off would disrupt occupants or inventory.

  • Projects seeking long-term performance with minimal maintenance and superior weather resistance.

  • Retrofit designs where protecting the original structure and reducing waste are top priorities.

238T Metal over Metal Recover Panel Project
238T Metal over Metal Recover Panel Project
238T Metal over Metal Recover Panel Project
238T Metal over Metal Recover Panel Project

238T Metal-Over-Metal Recover Top 3 Benefits

  1. No Tear-Off Required: Installs directly over existing metal roofs, saving time, labor, and disposal costs.

  2. Individual Panel Replaceability: The symmetrical 238T design allows individual panels to be removed or replaced anywhere on the roof.

  3. Onsite Rollforming: Panels up to 250’ reduce leak prone endlaps while also reducing labor, material handling, damage risk, storage needs, and jobsite debris.

Compare our retrofit & recover panels using the tool below.

For information on all McElroy Metal products, visit our full product library.


Panel
Seam Type
Rib Height
Panel Widths
Minimum Slope
Install Substrate
Clips
Substrate / Gauges
Coating
Notable Approvals / Tests
238T Metal-Over-Metal Recover – Standing Seam Metal Roof System
Mechanical seam (symmetrical)
2 3/8”
16", 18” or 24” (site formed only)
½:12
Solid Deck or Open Framing
Standard & multi-span clips; shingle recover clip available
24 GA Galvalume®-see notes below for additional options
Kynar 500® (PVDF); Galvalume® Plus (acrylic-coated)
UL 263 Class A; UL 580 Class 90; UL 2218 Class 4; ASTM E1592

Weathertightness Warranties

If your project requires a Weathertightness Warranty and you don’t already have a job specific Pre-Approval Form issued by McElroy Metal, click the button below to get started.

Shop Drawing Service

Running short of time to complete your own shop drawings? McElroy Metal can help. Click the button below to provide us some basic information and we’ll be in touch soon to discuss your project specifics.

Download Shop Drawings

If you’re creating your own shop drawings, click the button below to gain full access to our CAD and PDF Files.

Advantages of Recover vs. Replacement

benefits-check-red

50-60 year Service Life

benefits-check-red

Minimal Occupant Disruption

benefits-check-red

Individual Panel Replaceability

benefits-check-red

Extremely High Uplift Capacity

benefits-check-red

Long Length Panels Eliminate Leak Prone Panel Laps

benefits-check-red

Onsite Rollforming & 24" Wide Panels Reduce Labor

benefits-check-red

Onsite Rollforming Minimizes Damage, Storage Requirements & Debris

benefits-check-red

Original Building Design Protected

benefits-check-red

Multi Span Clips Offer Unparalleled Uplift

Helpful Videos

238T Metal-Over-Metal Recover

Roof Hugger is the best way to recover a through fastened or standing seam roof on open framing because the notched sub purlin increases the load carrying capacity of the original purlins.

High floating standing seam systems can be accommodated with special roof huggers and fasteners.

The tall clip recover system is designed to be installed over existing panels up to 1 1/2" tall, such as R-Panel.

The system utilizes tall clips that sit between the ribs of the existing panel and attach directly to the purlin below. Insulation fills the the air space between the two roofs.

The hat over zee clip system is an economical alternative to notched purlin for existing exposed fastener or low floating standing seam over open framing retrofit applications.

The two piece system allows for up to 6" of insulation between the two roofs. Optionally, the air space can be ventilated.

The infill approach is used when retrofitting standing seam panels installed over a solid deck. It also works well on existing exposed fastener or low floating standing seam installed over open framing.

Continuous insulation is one of the biggest benefits of this approach.

Roof Hugger is the best way to recover a through fastened or standing seam roof on open framing because the notched sub purlin increases the load carrying capacity of the original purlins.

High floating standing seam systems can be accommodated with special roof huggers and fasteners.

The tall clip recover system is designed to be installed over existing panels up to 1 1/2" tall, such as R-Panel.

The system utilizes tall clips that sit between the ribs of the existing panel and attach directly to the purlin below. Insulation fills the the air space between the two roofs.

The hat over zee clip system is an economical alternative to notched purlin for existing exposed fastener or low floating standing seam over open framing retrofit applications.

The two piece system allows for up to 6" of insulation between the two roofs. Optionally, the air space can be ventilated.

The infill approach is used when retrofitting standing seam panels installed over a solid deck. It also works well on existing exposed fastener or low floating standing seam installed over open framing.

Continuous insulation is one of the biggest benefits of this approach.

mcelroy-diagonal-navy-1

Single Ply vs. Metal Recover

Before covering an existing metal roof with single-ply, it's important to consider how that decision impacts the structural integrity of the building.   

Whether you're a building owner, design professional, or contractor, the third-party articles below highlight critical issues and engineering considerations that bear serious consideration.

blog.mcelroymetal.comhs-fshubfssocial-suggested-imagesblog.mcelroymetal.comhs-fshubfsPhoto GalleryRetrofit Applications7th Street Wharf- During N

Comparison of Retrofit Systems Over Existing Metal Roofs

recover-videos-thumb

Recovering Existing Metal Roof Systems Requires Diligence

Think Twice About a Single-Ply Roof on a Metal Building

Think Twice About a Single-Ply Roof on a Metal Building

Charlie-Smith

Need help?

Meet Charlie, Our Recover Specialist

Before and After

7th-street-wharf-during-new-orleans-la
7th-street-wharf-after-new-orleans-la
Alexander II_138T Recover_Ash Gray_Before
Alexander II_138T Recover_Ash Gray_Finished
Central GA Tech_Retrofit_238T_Medium Bronze_Straight Down shot_before
Central GA Tech_Retrofit_238T_Medium Bronze_Straight Down shot_Finished
SW-Houston-Before
SW-Houston-After
1st-inspection-before
1st-inspection-after
map-red

Find a Distributor / Contractor Near You

Whether you’re building a new home or planning renovations, a metal roof can deliver long-term cost savings and comfort. To explore your options and find the product that meets your aesthetic and budgetary needs, contact a McElroy Metal distributor or contractor in your area today. We can’t wait to help make your dream home a reality.

Find a Contractor